Number of Charging Interfaces: | One Pile with Multiple Charges |
---|---|
Location: | Public Use |
Installation: | Floor Type |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Electrical Input | |
Input rating | 480 + 5%Vac, 60Hz |
Wiring | L1, L2, L3, Neutral & Earth |
THDi | <5% |
Electrical Output | |
Max DC output power | CCS1:240kW* CHAdeMO:60KW |
Number of EV served | 2 |
Output voltage | CCS1:200-1000Vdc CHAdeMO:200-500Vdc |
Maximum Output Current | CCS1:250A@960V,240A@1000V CHAdeMO:125A@480V,120A@500V |
Charging cables maximum current | CCS1:250A CHAdeMO:125A |
Efficiency | ≥94% (@25°0,Nominal output) |
Power Factor | 0.99 (@Full load) |
User Interface & Control | |
Display | 7" LCD Touch Panel for interaction |
Support Language | English, (supports customization in other languages) |
Push Buttons | Emergency stop button |
RFID Reader | ISO /IEC 14443 type A/B |
Charging interface | Comply with SAE J1772 |
Environmental | |
Storage Temperature | -40°0~70°0 |
Operating Humidity | -30°0~50°0 |
Altitude | ≤2000m, Over 2000m, derate. |
Humidity | 5%~95% No condensation |
Communication | |
Network Interface | 4G Ethernet, Wifi available upon request |
Protocol | Proprietary Protocol or OPP 1.6J |
Vehicle communication | ISO/1EC 15118-1/2/3/4/5 • DIN SPEC-70121 , SAE J2847 |
Mechanical | |
Ingress Protection | IP54, NEMA type 3R |
Enclosure Protection | IK10 (cabinet) / IK08 (touchscreen) |
Cooling | Forced air |
Charging Cable Length | 5m, optional: 3.5 m / 7.5 m |
Dimension (W× H× D) | 820mm*2000mm*750mm |
Wheight | About 427 kg |
Installation | Floor mounted |
Safety | |
Safety Compliance | UL2202 ; UL2231-1, UL2231-2 CA C22.2 NO.107.1 , CSA C22.2 NO.281.1-12 . |